Hot Beverage Maker User Manual

— 5 —
DIRECT STEAM COUNTERTOP TILTING KETTLES
Before installing, verify that the direct steam
supply required for the equipment covered by
this manual agrees with the specifications on
the machine data plate, located on the back of
the unit. If the direct steam supply does not
agree with the equipment requirements, do
not proceed with the installation. Contact your
dealer or Vulcan-Hart immediately.
UNPACKING
This kettle was inspected before leaving the
factory. The transportation company assumes
full responsibility for safe delivery upon
acceptance of the shipment.
Immediately after unpacking, check for
possible shipping damage. If kettle damage is
found, save the packaging material and
contract the carrier within 15 days of delivery.
INSTALLATION CODES AND
STANDARDS
In the United States, Vulcan kettles must be
installed in accordance with:
1 State and local codes
2 NFPA Standard NFPA-96, Vapor Removal
from Cooking Equipment, latest edition,
available from the National Fire Protection
Association, Batterymarch Park, Quincy,
MA 02269
In Canada, Vulcan kettles must be installed in
accordance with local codes.
LOCATION
The K6DTT and K12DTT countertop tilting
kettles must be positioned on a firm stand or
countertop and secured in place.
MINIMUM CLEARANCE
TABLE 2. MINIMUM CLEARANCE
REQUIREMENTS
Capacity in Clearance in
Gallons Inches (Back)
6 5.25
12 6.5
INSTALLING K6DTT ON COUNTER
OR STAND
Vulcan kettles must be permanently
mounted on a suitable, level counter or
stand. Place unit in a drained location.
Fig. 3 Mounting Hole Location
1. Position the kettle on the counter with
sufficient rear clearance from the wall to
allow the kettle to tilt completely without
obstruction according to the Minimum
Clearance Requirement Chart, Table 2.
Allow space for plumbing.
INSTALLATION