User Guide
ELECTRIC COUNTER TOP TILTING KETTLES - GENERAL
SPECIFICATIONS
Reservoir Jacket Fluid
• Water - Use only distilled water for partial re-filling of the jacket (purchase locally).
• Dowfrost heat transfer fluid Part No. 558038 (5 gallon). Use during a complete re-fill of the jacket with new
fluid. Refer to service procedures for volumes.
Electric
The kettle models listed in this manual, with exception of 480V steamers, are shipped pre-wired for 208/60/3
operation. Kettle heating element wiring change is required if connecting to 208/60/1, 240/60/1 or 240/60/3
electrical service.
ELECTRICAL SPECIFICATIONS
Volts Phase
K6ETT
*
K12ETT K20ETT
Total
KW
Amps
Total
KW
Amps
Total
KW
Amps
208 1 7.50 36 12 58 12 58
240 1 10.0 42 16 67 16 67
208 3 7.5 22 12 33 12 33
240 3 10.0 26 16 39 16 39
480 3 7.50 9 12 14 12 14
*K6ETT only - Heating elements on 208/240VAC three phase machines are
not wired as a balanced load.
F35496 (August 2009)