User Guide
ELECTRIC COUNTER TOP TILTING KETTLES - REMOVAL AND REPLACEMENT OF PARTS
HEATING ELEMENT
1. Open pressure relief valve until reservoir jacket
is completely vented.
2. Tilt kettle to expose the heater access cover.
3. Remove three screws where indicated. Loosen
remaining screw and allow cover to rotate out of
way.
4. Note lead wire locations and disconnect wires
from heating element.
5. Remove mounting bolts securing heating
element to kettle.
6. Reverse procedure to install. Use a new heating
element seal whenever installing heating
element. Torque mounting bolts to 40 ft-lbs and
tighten in an alternating pattern.
7. Remove air from reservoir jacket as outlined
under VENTING.
8. Check for proper operation and leaks around
heating element.
NOTE: On K6ETT only, element lengths are
staggered to fit the contour of the kettle bottom.
Install with the shortest element toward the bottom of
kettle.
F35496 (August 2009)Page 7 of 28