Hot Beverage Maker User Manual
— 6 —
DIRECT STEAM COUNTERTOP TILTING KETTLES
2. On countertop, drill two 1" holes on 8
1
/2"
centers for the two kettle leg stanchions.
3. Remove the mounting locknuts and
washers [
1
/2" NPT (NPSL) nuts] from the
bottom of the legs.
4. Prepare a clean, dry surface according to
package directions on a high grade NSF
listed sealant.
5. Apply sealant to the flared edge of the
stanchions.
6. Insert the threaded portion of the
stanchions through the holes. Install
washers and lock nuts and tighten.
7. Wipe off excess sealant.
INSTALLING K12DTT ON
TABLE OR STAND
Figure 4: K12DTT mounting hole location
1. Drill four
7
/16" holes in table or stand top as
shown in Figure 4.
2. Drill two 1" holes in table or stand top as
shown in Figure 4.
3. Install
3
/8" anchor couplings in the 1" holes.
4. Set kettle on table or stand top, align holes,
and attach using four
5
/16" - 18 hex head
screws and lock washers.
5. Using flexible steel or copper tubing,
connect steam and condensate lines under
the kettle.
PLUMBING CONNECTIONS
Plumbing connections must comply with
applicable sanitary, safety and plumbing
codes.
Steam Supply Connection
TABLE 3. STEAM TABLE
Fast Boil Medium Boil Stock Boil
12 minutes 20 minutes 30 minutes
Time to boil lbs/hr kg/hr lbs/hr kg/hr lbs/hr kg/hr
12 gallons 78 36 43 20 29 13
MODEL TRUE WORKING CAPACITY 4OZ. SERVINGS
K12DTT 12 gallons, 48 quarts 384
45 liters
1. Install a steam shut off valve in the steam
supply line, preferably near the kettle for
ease of maintenance.
2. Install a pressure reducing valve (if supply
pressure is more than 50 PSI), pressure
relief valve, and strainer.
3. Install steam traps in the line to eliminate water
in the incoming steam line. Mount in a drip leg
on the supply line, not directly in the supply line.
4. Install steam line pressure gauge to
determine actual pressure to kettle.
5. Connect the steam supply line (
1
/2" pipe size) to
the steam inlet fitting on the right leg (stanchion).
Drain Connection
1. Install a steam steam strainer and trap in the
condensate line (left side) near the kettle and
run a condensate return line to the drain.
2. Install a check valve and gate shut off valve
near the kettle if the condensate line will be
going to the boiler.
Relief
Valve
50 PSI
Pressure
Gauge
Pressure
Reducing
Valve
Union
Shutoff
Valve
Steam Trap
on Drip Leg
Steam
Trap
Check
Valve
Strainer
Strainer
STEAM
IN
TO
KETTLE
STEAM
IN
TO DRAIN
TO DRAIN OR BOILER
CONDENSATE RETURN
FROM
KETTLE
STEAM LINE PLUMBING
CONDENSATE RETURN PLUMBING
Figure 5: K6DTT Plumbing