MAINTENANCE 
     Hot oil and hot parts can cause burns. Use care when operating, 
  cleaning, and servicing the fryer. 
     Spilling hot fryer compound can cause severe burns. Do not 
   move fryer without draining all frying compound from the tank. 
FLUE VENT INSPECTION 
When the fryer is cool, inspect annually. Check the flue and clear any obstructions. 
Service in the US and Canada 
Contact you local Vulcan-Hart Service office or address on the front of this manual. 
ALARMS AND ERROR MESSAGES 
NO OR LOW GAS SUPPLY – If no action is taken after 90 seconds, an alarm sounds 
continuously, the heat demand is disabled and any running cooking cycles are cancelled. 
The digital display the following message: 
        “D” Solid State – IGNITION LOCKOUT 
 “C” Computer – IGNITION  LOCKOUT CHECK GAS SUPPLY 
The fryer must be turned off, then back on to re-initialize the control and to have normal 
functions resumed. 
OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running 
cooking cycles are cancelled. All operator buttons are disabled. The digital control displays 
the following message: 
        “D” Solid State – OPEN PROBE 
        “C” Computer – PROBE OPEN 