Fryer User Manual
VK SERIES GAS FRYERS 
VULCAN-HART        F-32971 Rev. F (December 2011) 
-9- 
  When installing a quick disconnect you must also install a means for limiting the 
movement of the fryer. This device will prevent the gas line or quick disconnect 
  from being strained. The restraining device should be attached to the cutout on the 
  back panel. See illustration for location. 
  The fryer must be installed with a connector (not supplied by Vulcan) complying 
with the above codes. 
  The fryer must be installed with restraining means to guard against 
transmission of strain to the connector. See illustration. 
  The fryer must be installed with the casters provided. 
  If the restraint is ever to be disconnected, first turn the gas supply off. If   
    disconnection of the restraint is necessary, to reconnect this restraint after the fryer 
    has been returned to its originally installed position. 
LEVELING THE FRYER 
Check the level of the fryer by placing a level on top of the fryer after gas connections 
have been made. 
Ensure that the fryer is level front-to-back and side-to-side in the final installed position. 
If using casters, lock the wheels after unit is level. 