Electric Steamer User Manual

16
SERVICE CONNECTIONS
GAS HEAT, VSX42GT FIG. 9
LEGEND
A. GAS CONNECTION:
3
4” NPT.
B. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT
MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR
OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF
THIS CONNECTION.)
C. DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY
3
1
2” IN DIAMETER. (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY
UNDER UNIT FRAME. DO NOT CONNECT SOLIDLY TO ANY DRAIN
CONNECTION.)
D. COLD SUPPLY WATER CONNECTION:
1
4” NPT FOR BOILER DRAIN &
COMPARTMENT DRAIN COLD WATER CONDENSERS, AND BOILER FEED.
NOTE: DIMENSIONS WHICH LOCATE THE ABOVE CONNECTIONS HAVE A
TOLERANCE OF ± 3 IN. (± 75 MM). NORMAL DIMENSIONS ARE IN INCHES.
DIMENSIONS IN ( ) ARE IN MILLIMETERS.
EQUIPMENT CLEARANCES
TO COMBUSTIBLE CONSTRUCTION
REAR: 6 IN. MIN. (150 MM.)
LEFT SIDE: 6 IN. MIN. (150 MM.)
RIGHT SIDE: 6 IN. MIN. (150 MM.)