Note that except for setting the receivers channel, all other modes can be entered after pushing the CLOSE_6,
CLOSE_7 and CLOSE_8 buttons once.
Example 1:
To change settings from factory default:
Channel 5, Momentary, Reversed, Disable ALL button, SPST and run time for 62 seconds. Use the following
sequences:
Press STOP, CLOSE_7 and OPEN_7
Press OPEN_1 At this point program mode is entered and channel 1 will receive the changes.
Press CLOSE_1 Flag to change channel.
Press OPEN_5 Channel 1 is now channel 5 when programming mode exit.
Note: Partial example if only changing the channel is required; press STOP to exit
programming mode.
Press CLOSE_6 Flag to change actions in Group 4.
Press OPEN_1 Momentary
Press OPEN_2 Reversed
Press OPEN_3 Disable ALL buttons
Press CLOSE_7 Flag to change action in Group 5.
Press OPEN_1 SPST
Press CLOSE_8 Flag to change action in Group 6.
Press OPEN_10, OPEN_6, OPEN_2 Run Time of 62 seconds
Press STOP Exit programming mode
Example 2:
To change settings of Example 1:
Channel 12, and run time for 129 seconds. Use the following sequences:
Press STOP, CLOSE_7 and OPEN_7
Press OPEN_5 At this point program mode is entered and channel 5 will receive the changes.
Press CLOSE_1 Flag to change channel.
Press OPEN_12 Channel 5 is now channel 12 when programming mode exit.
Press CLOSE_8 Flag to change settings in Group 6.
Press OPEN_1, OPEN_2, OPEN_9 Run Time of 129 seconds
Press STOP Exit programming mode
Example 3:
To reset EVERYTHING to factory default:
Press STOP, CLOSE_7 and OPEN_7
Press OPEN_ALL hold for 5 seconds until blink.
Press STOP Exit programming mode
Important note: If you have multiple receivers sharing an IR sensor Set each receiver to different channel
before chaining them together. If don’t do so, as programming receiver 1 will program them all.
Warning: Do not turn off power while the programming LED is on you may lose all your settings.