User manual

Chapter 6 System Configuration
© National Instruments Corporation 6-13 VXI-MXI-2 User Manual
MXIbus Link:
MXIbus #1
Device:
MXIbus Device A
Number of logical addresses required by device:
3
Range =
E0
E3
Round total number up to the next power of two:
4 (2
2
)
Size =
8-2 = 6
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
0
Total number of logical addresses required by this device: =
3
Range =
E0
E3
Round total number up to the next power of two:
*
4 (2
2
)
Size =
8-2 = 6
Device:
MXIbus Device B
Number of logical addresses required by device:
1
Range =
E4
Round total number up to the next power of two:
1 (2
0
)
Size =
8-0 = 8
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
0
Total number of logical addresses required by this device: =
1
Range =
E4
Round total number up to the next power of two:
*
1 (2
0
)
Size =
8-0 = 8
Device:
VXIbus Mainframe #2
Number of logical addresses required by device:
23
Range =
C0
DF
Round total number up to the next power of two:
32 (2
5
)
Size =
8-5 = 3
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links:
+
0
Total number of logical addresses required by this device: =
23
Range =
C0
DF
Round total number up to the next power of two:
*
32 (2
5
)
Size =
8-5 = 3
Device:
VXIbus Mainframe #3
Number of logical addresses required by device:
6
Range =
80
87
Round total number up to the next power of two:
8 (2
3
)
Size =
8-3 = 5
List other MXIbus links to this mainframe:
MXIbus #3
Number of logical addresses required by
additional MXIbus links:
+
32
Total number of logical addresses required by this device: =
40
Range =
A0
BF
Round total number up to the next power of two:
*
64 (2
6
)
Size =
8-6 = 2
Device:
Number of logical addresses required by device:
Range =
Round total number up to the next power of two:
Size =
List other MXIbus links to this mainframe:
Number of logical addresses required by
additional MXIbus links: +
Total number of logical addresses required by this device: =
Range =
Round total number up to the next power of two:
*
Size =
Total Number of Logical Addresses Required:
101
(Add numbers after the “
*
”) Range =
80
FF
Round Total Number up to Next Power of Two:
128 (2
7
)
Size =
8-7 = 1
Figure 6-8. Worksheet 2 for MXIbus #1 of Example VXIbus/MXIbus System