User manual

Chapter 6 System Configuration
© National Instruments Corporation 6-27 VXI-MXI-2 User Manual
VXI-MXI-2
VXI-MXI-2
VXI-MXI-2
VXI-MXI-2
VXI-MXI-2
Multiframe
Resource
Manager
VXIbus
Mainframe
#1
MXIbus
Device
A
MXIbus
Device
B
VXIbus
Mainframe
#2
VXIbus
Mainframe
#3
VXI-MXI-2
VXIbus
Mainframe
#6
VXI-MXI-2
VXIbus
Mainframe
#5
VXI-MXI-2
VXIbus
Mainframe
#4
MXIbus #2
MXIbus #3
MXIbus #1
Level 1
Level 2
Figure 6-19. Example VXIbus/MXIbus System Diagram
Table 6-4. Example VXIbus/MXIbus System Required A16 Space
Device
Amount of A16
Space Required
VXIbus Mainframe #1 16 KB
MXIbus Device A 512 B
MXIbus Device B 0 B
VXIbus Mainframe #2 0 B
VXIbus Mainframe #3 4 KB
VXIbus Mainframe #4 2 KB
VXIbus Mainframe #5 1 KB
VXIbus Mainframe #6 2 KB