User manual

Chapter 3 VXI-MXI-2 Configuration and Installation
© National Instruments Corporation 3-11 VXI-MXI-2 User Manual
The VXI-MXI-2 can also drive or receive the MXIbus CLK10 signal.
Switch S7 controls whether the VXI-MXI-2 drives MXIbus CLK10
from the VXIbus CLK10 or receives MXIbus CLK10. As shown earlier
in Figure 3-5c, if W3 is configured to use the MXIbus CLK10 to
generate the VXIbus CLK10 signal, switch S7 must be configured to
receive MXIbus CLK10. This is shown again in Figure 3-7a below.
If you change the S7 setting to drive CLK10 out the MXIbus, do not set
the W3 jumper setting to receive the MXIbus CLK10; instead use the
settings shown in Figure 3-5a or 3-5b as appropriate.
Warning: Do not configure more than one MXIbus device to drive the MXIbus
CLK10. Having a second device driving MXIbus CLK10 could result in
damage to the device.
Figure 3-7 shows the configuration settings for receiving and driving
MXIbus CLK10, respectively.
a. Receive CLK10 from MXIbus (Default) b. Drive MXIbus CLK10 from VXIbus CLK10
S7
Drive CLK10 out MXIbus
Receive CLK10 from MXIbus
S7
Drive CLK10 out MXIbus
Receive CLK10 from MXIbus
Figure 3-7. Receiving or Driving MXIbus CLK10