User manual

Chapter 3 VXI-MXI-2 Configuration and Installation
© National Instruments Corporation 3-13 VXI-MXI-2 User Manual
MXIbus Termination
The first and last MXIbus devices connected to the MXIbus—whether
it is a single MXI-2 cable or daisy-chained MXI-2 cables—must
terminate the MXIbus. Any MXIbus devices in the middle of a MXIbus
daisy chain must not terminate the MXIbus.
The VXI-MXI-2 automatically senses whether it is at either end of the
MXIbus cable to terminate the MXIbus. You can manually control
MXIbus termination by defeating the automatic circuitry. Use switches
1 and 2 of the four-position switch at location U35 to control whether
MXIbus termination is automatic (Figure 3-9a), on (Figure 3-9b), or off
(Figure 3-9c). The settings of switches 3 and 4 have no effect on
MXIbus termination.
Use switch 2 of U35 to select whether you want the VXI-MXI-2 to
automatically control termination of the MXIbus. Switch 1 of U35 lets
you manually control whether to terminate the MXIbus when automatic
termination is turned off. Switch 1 has no effect when switch 2 is set
for automatic MXIbus termination; you must turn off automatic
termination if you want to manually control termination.