Chapter 4 VXI-MXI-2/B Configuration and Installation
© National Instruments Corporation 4-9 VXI-MXI-2 User Manual
The VXI-MXI-2/B can also be configured to drive the external CLK
SMB signal from the VXIbus CLK10 signal. Switch S7 controls
whether the VXI-MXI-2/B drives or receives the external CLK SMB
signal. If you change the S7 setting to drive CLK10 out the external
CLK10 SMB connector, do not set the W1 jumper to receive the SMB
CLK10 signal; instead use the settings shown in either Figure 4-5a or
Figure 4-5c as appropriate.
When switch S7 is set so that the VXI-MXI-2/B receives the SMB
CLK10 signal, you have the option to add a 50 termination to the
signal by setting switch S6. S6 is unused—its setting does not matter—
when S7 is configured to drive the external CLK SMB signal.
You can use an additional switch, S3, to control the polarity of the
external CLK SMB signal when S7 is configured to drive it. S3 is
unused—its setting does not matter—when S7 is configured to receive
the external CLK SMB signal.
Figure 4-6 shows four configuration settings for the VXI-MXI-2/B.
Figure 4-6a shows the default configuration, which is for driving the
inverted external CLK SMB. Use the settings of Figure 4-6b to drive
the noninverted external CLK SMB signal. Figure 4-6c illustrates the
setting for receiving the external CLK SMB signal. Finally, you can
configure the switches as shown in Figure 4-6d to receive the external
CLK SMB signal with a 50 termination.
Note:
The settings of any switches shown with this pattern ( ) have no
bearing on the configuration described in any of the following figures.