Chapter 5 Register Descriptions
VXI-MXI-2 User Manual 5-18 © National Instruments Corporation
Extender A32 Window Register (VWR3)
VXIbus Configuration Offset: 10 (hex)
Attributes: Read/Write 16, 8-bit accessible
15 14 13 12 11 10 9 8
0 A32EN A32DIR 1 1 A32SIZE[2] A32SIZE[1] A32SIZE[0]
76 54 321 0
A32BASE[7] A32BASE[6] A32BASE[5] A32BASE[4] A32BASE[3] A32BASE[2] A32BASE[1] A32BASE[0]
You can use this register to control the mapping of VMEbus A32 space between the
VXIbus and the MXIbus. When programming this register, you do not need to consider
any VMEbus A32 space that the VXI-MXI-2 itself requires. This is because the A24/A32
Decoder has a higher priority than VWR3, and the VXI-MXI-2 will respond to its A32
accesses from both the VXIbus and the MXIbus. This register conforms to the VXIbus
Mainframe Extender specification.
This register takes on a different form when the CMODE bit in the VXI-MXI-2 Control
Register (VMCR) is set. This different form does not comply with the VXIbus
Mainframe Extender specification, and the CMODE bit should not be set when using a
VXIbus multiframe Resource Manager. For more information on the CMODE bit, refer
to the VMCR register description.
To accommodate 8-bit masters that write to this register, the window is not enabled until
the lower byte of the register is written. Therefore, 8-bit masters should write the upper
byte first, followed by the lower byte.
Bit Mnemonic Description
15 0 Reserved
This bit is reserved and returns 0 when read. This
bit can be written with any value.
14 A32EN Extender A32 Window Enable
Writing a 1 to this bit enables mapping of
VMEbus A32 space through the Extender A32
Window. When this bit is cleared, no VMEbus
A32 accesses are mapped between the VXIbus
and the MXIbus. This bit is cleared by a hard
reset and is not affected by a soft reset.