Chapter 5 Register Descriptions
© National Instruments Corporation 5-25 VXI-MXI-2 User Manual
1 SRIN SYSRESET* In
Setting this bit causes the VXI-MXI-2 to route
the SYSRESET* signal from the MXIbus to the
VXIbus. When this bit is clear, SYSRESET* is
ignored on the MXIbus. This bit is cleared by a
hard reset and is not affected by a soft reset.
0 SROUT SYSRESET* Out
Setting this bit causes the VXI-MXI-2 to route
the SYSRESET* signal from the VXIbus to the
MXIbus. When this bit is clear, SYSRESET* is
ignored on the VXIbus. You can route
SYSRESET* in both directions simultaneously.
This bit is cleared by a hard reset and is not
affected by a soft reset.