User`s manual

www.vxitech.com
Tektronix to VXI Technology Cross-Ref. Guide 125
In many ATE applications, a termination panel for the instrumentation is utilized. This termination
panel will have connectors that mate to the UUT or an intermediate test fixture. A termination
panel may take the form of an Interconnect Assembly (ICA) made by manufacturers such as
Virginia Panel or Macpanel. In either case, it is desirable to maintain the same I/O layout at the
panel to avoid costly redesign of test fixturing or UUT cable assemblies.
VXI Technology offers a couple of options that prevent the need for any interface panel to UUT
redesign as follows:
wired funnel assemblies that mate directly to the SM73A308 front panel
custom cabling between SM73A308 front panel and ICA/termination panel
For customers who plan on developing their own cabling between the SM73A308 and the
termination panel, this section provides a cross-reference pinout table between the 73A308 and the
SM73A308 in Table 13-1 and Table 13-2.