CT-100B SERIES SIX-SLOT VXIBUS CHASSIS USER’S MANUAL 82-0042-000 Rev. April 7, 2003 VXI Technology, Inc.
VXI Technology, Inc.
www.vxitech.com TABLE OF CONTENTS INTRODUCTION Certification ....................................................................................................................................................... 4 Warranty ............................................................................................................................................................ 4 Limitation of Warranty .........................................................................................................
VXI Technology, Inc. CERTIFICATION VXI Technology, Inc. (VTI) certifies that this product met its published specifications at the time of shipment from the factory. VTI further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (formerly National Bureau of Standards), to the extent allowed by that organization’s calibration facility, and to the calibration facilities of other International Standards Organization members.
www.vxitech.com DECLARATION OF CONFORMITY Declaration of Conformity According to ISO/IEC Guide 22 and EN 45014 MANUFACTURER’S NAME VXI Technology, Inc. MANUFACTURER’S ADDRESS 2031 Main Street Irvine, California 92614-6509 PRODUCT NAME Six-Slot VXIbus Chassis MODEL NUMBER(S) CT-100B PRODUCT OPTIONS All PRODUCT CONFIGURATIONS All VXI Technology, Inc.
VXI Technology, Inc.
www.vxitech.com GENERAL SAFETY INSTRUCTIONS Review the following safety precautions to avoid bodily injury and/or damage to the product. These precautions must be observed during all phases of operation or service of this product. Failure to comply with these precautions, or with specific warnings elsewhere in this manual, violates safety standards of design, manufacture, and intended use of the product. Service should only be performed by qualified personnel.
VXI Technology, Inc. WARNINGS (CONT.) Avoid Electric Shock To avoid electric shock or fire hazard, do not operate this product with the covers removed. Do not connect or disconnect any cable, probes, test leads, etc. while they are connected to a voltage source. Remove all power and unplug unit before performing any service. Service should only be performed by qualified personnel. Ground the Product This product is grounded through the grounding conductor of the power cord.
www.vxitech.com SUPPORT RESOURCES Support resources for this product are available on the Internet and at VXI Technology customer support centers. Internet Support E-mail: support@vxitech.com Web Address: http://www.vxitech.com Telephone Support (U.S.) Tel: (949) 955-1894 West Coast (216) 447-8950 East Coast Fax: (949) 955-3041 West Coast (216) 447-8951 East Coast VXI Technology Headquarters Technical Support VXI Technology, Inc.
VXI Technology, Inc.
www.vxitech.com SECTION 1 INTRODUCTION INTRODUCTION The CT-100B portable C-size VXIbus mainframe provides cost-effective test situations in a small footprint. When using VMIP instruments such as DMMs, waveform generators, digitizers, etc., complete test scenarios can easily be configured.
VXI Technology, Inc. GENERAL DESCRIPTION The CT-100B chassis is a portable, C-size, six-slot, VXIbus compatible chassis that conforms fully to VXIbus Specification Revision 1.4. The chassis employs a multi-layer backplane to ensure premium VXIbus and VMEbus performance and provides all power supplies required by the VXIbus specification. The CT-100B supports conventional existing rack designs through an optional rack mounting kit (see Section 2).
www.vxitech.com FLEXIBILITY The CT-100B is designed to provide flexibility of use in bench-top and rack-mount applications, as well as in portable environments. The outside cover is removable for easy access to the VXIbus modules during bench-top development, troubleshooting or calibration. For rack-mount applications, a rack-mount kit allows the CT-100B to mount flush or be recessed four inches.
VXI Technology, Inc. CT-100B SERIES SPECIFICATIONS GENERAL SPECIFICATIONS SIZE 8.2” W x 15” H x 21” D without feet and handle 8.5” W x 17” H x 21” D with feet and handle Six C-Size VXIbus card slots WEIGHT 28 lbs (12.7 kg) VXIbus Version 1.4 MTTR 30 min ENVIRONMENTAL SPECIFICATIONS OPERATING LOCATION This chassis should be operated indoors in a controlled environment, protected from exposure to the elements (i.e. direct sunlight, precipitation, wind, etc.).
www.vxitech.com POWER SPECIFICATIONS USEABLE POWER 450 W at 40°C DC Supply Voltage Voltage +5 V -5.2 V -2 V +12 V -12 V +24 V -24 V Peak Current (IMP) 35 A 25 A 7A 4A 4A 4A 4A Dynamic Current (IMD) 5A 4A 2A 2A 1.5 A 3A 3A Output Voltage POWER INPUT Input Voltage AC Frequency Fuse 115 V Operation 220 V Operation +5VSTBY Voltage Allowed Variation +5 V -5.2 V -2 V +12 V -12 V +24 V -24 V +0.25 V / -0.125 V -0.26 V / +0.125 V -0.10 V / +0.72 V +0.60 V / +0.36 V -0.60 V / +0.36 V +1.20 V / -0.72 V -1.
VXI Technology, Inc. COOLING SPECIFICATIONS COOLING REQUIREMENTS (TBD) 60 W/slot for a 10°C Rise 80 W/slot for a 15°C Rise AIR FLOW PATH Air is drawn into the chassis from the rear and is pressurized below the cards. The air is then distributed across all slots along the total length of each slot and is exhausted through the top of the mainframe. When the mainframe is rack mounted, allow approximately 2 inches (50 mm) of clearance at the top and rear for proper airflow. Pressure Drop - mm H2O 2.5 2.0 1.
www.vxitech.com 21.000 (533.40) 8.100 (205.74) 0 1 VXI Technology CT100B Mainframe VOLTAGE MONITOR -2V + 5V STBY -12V -5.2V + 24V + 12V -24 V + 5V 16.404 (416.66) 14.979 (380.47) 0 1 2 3 4 5 bus Note: Measurements in parenthesis are in millimeter. 0.343 (8.71) +5 STANDBY +5 STANDBY RETURN FUSE 10A 115VAC 5A 230VAC FIGURE 1.
VXI Technology, Inc.
www.vxitech.com SECTION 2 INSTALLATION INTRODUCTION When the CT-100B is unpacked from its shipping carton, the contents should include the following items: (1) CT-100B Six-Slot Chassis (1) CT-100B Module User’s Manual (this manual) (2) Replacement fuses, one 10 A slow blow, one 5 A slow blow (1) Power cord All components should be immediately inspected for damage upon receipt of the unit.
VXI Technology, Inc.
www.vxitech.com RACK MOUNT OPTION INSTALLATION OVERVIEW This section contains the procedures for installing a CT-100B chassis in a standard 19” relay rack. The available rack mounting options are: Option 52 – Rack Mount Ear Kit Option 53 – Rack Mount Door Kit Option 57 – 20” Slide Kit Option 58 – 24” Slide Kit The rack mount ear kit provides the basic hardware necessary to rack mount the CT-100B chassis.
VXI Technology, Inc. RACK MOUNT KIT INSTALLATION The rack mount kit (Option 59) provides the basic hardware necessary to rack mount the CT-100B chassis. With the chassis being only 15” wide, standard rack support rails cannot provide mechanical support to the chassis. If the equipment mounted below the CT-100B cannot provide mechanical support to the chassis, either 20” or 24” rack slides will be required to support the chassis when installed into the rack.
www.vxitech.com Black Oxide Pan Head Phillips Screws (x4) Rack Mount Ears (x2) Flush Rackmount Configuration * Recessed Rack Mount Installation Shown FIGURE 2.
VXI Technology, Inc. RACK SLIDE INSTALLATION (20” AND 24”) The 20” and 24” slide hardware kits (Options 63 and 64, respectively) provide standard flanges to mount the slides into standard EIA relay racks. It should be noted that the slide flanges in the front should be installed behind the rack’s front panel mounting rails. This will allow the rack mounting ears to sit flush with the front of the rack.
www.vxitech.com 5. Locate the slide hardware kit provided. Install the rack flanges to the slides as required by the application using the hardware in the kit. Note that the screws are inserted from the inside of the slides and the nuts would show on the outside. 6. Install the slides to the mounting brackets already installed on the chassis using the provided hardware.
VXI Technology, Inc. RACK MOUNT DOOR KIT INSTALLATION The rack mount door kit (Option 60) provides the necessary hardware to install a 1/8” thick aluminum door in front of the rack mounted chassis. This option requires that the rack mount ear kit also be installed and configured for recessed mounting. The door may be customer modified to hold connectors, controls, indicators and similar components. REQUIRED TOOLS 1. 2. 3.
www.vxitech.com 1/2” Pan Head Phillips Screws (x2) Front Door Stop 6-32 Hex Nuts (x2) Rackmount Braces (x2) Door Latch Kit Front Door, Aluminum 3/8” Flat Head Phillips Screws (x4) Hinges (x2) 3/8” Pan Head Black Oxide Phillips Screws (x8) FIGURE 2.
VXI Technology, Inc. ACRYLIC RACK MOUNT DOOR KIT INSTALLATION An acrylic rack mount door is offered as an alternative to the aluminum rack mount door. The kit (Option 65) provides the necessary hardware to install a 1/8” thick acrylic door in front of the rack mounted chassis. An installation diagram is provided on the following page for ease of assembly. This option requires that the rack mount ear kit also be installed and configured for recessed mounting. REQUIRED TOOLS 1. 2. 3.
www.vxitech.com 6. Locate the four tapped holes on the front surface of the rack mount ear to which the door is to be attached. 7. Install the door by its hinges to the rack mount ear using four 3/8” black pan head screws provided with the option kit. 8. Test that the door opens and closes smoothly and adjust the latch as necessary to secure the door when latched close.
VXI Technology, Inc.
www.vxitech.com SECTION 3 OPERATION INTRODUCTION There are no operating instructions required for the CT-100B VXIbus chassis. After the chassis is installed, operation is completely transparent to the operator. Just plug in the instruments then power up the chassis. The power supply lines are monitored and displayed on the front panel to provide user feedback of correct operation (see Figure 3-2).
VXI Technology, Inc. 0 1 VXI Technology CT100B Mainframe VOLTAGE MONITOR -2V -24V -12V + 5V + 24V + 12V STBY -5.
www.vxitech.com INDEX # 5V STANDBY................................................................ 12 A airflow....................................................................... 12, 15 B backplane........................................................................ 12 backplane configuration.................................................. 12 D DC supply voltage .......................................................... 16 dimentions .............................................................