CT-400 Operation 49
CT-400 MONITOR BOARD - SIGNALS
Connector J210
AMBTEMPOUT – Analog output reflecting the temperature of the air entering the mainframe.
This is a non-linearized signal. See
Figure 3-3 for a voltage to temperature conversion.
Voltage to Temperature Conversion
0
5
10
15
20
0 1020304050607080
Temperature (°C)
Voltage (V)
Ambient Temp AMBTEMPOUT Ambient Temp AMBTEMPOUT
0 °C 3.27 V 40 °C 7.19 V
10 °C 3.76 V 50 °C 9.44 V
20 °C 4.50 V 60 °C 12.55 V
25 °C 5.00 V 70 °C 16.77 V
30 °C 5.60 V
FIGURE 3-3: TEMPERATURE / VOLTAGE CONVERSION
PWSOTEMP* - This low true open collector output signals a power supply over-temperature
condition. This fault condition occurs when the maximum internal temperature of the power
supply is exceeded. This signal is pulled up to +5 V with a 4.7k resistor internally.
PWSOPWR* - This low true open collector output signals a power supply over-power condition.
This fault will occur when more power is demanded from the power supply than it can provide.
This signal is pulled up to +5 V with a 4.7k resistor internally.
PWSOVOLT* - This low true open collector output signals a power supply over-voltage
condition. This fault occurs when one of the voltages produced by the power supply exceeds its
maximum value. This signal is pulled up to +5 V with a 4.7k resistor internally.
PWSOCUR* - This low true open collector output signals a power supply over-current condition.
This fault occurs when the maximum current of a voltage is exceeded. This signal is pulled up to
+5 V with a 4.7k resistor internally.
AMBOTEMP* - This low true open collector output signals a power supply over-temperature
condition. This fault occurs when the ambient air temperature exceeds 55 °C. This signal is pulled
up to +5 V with a 4.7k resistor internally.