Specifications
Simple Data Logger Example
dlgr1419.vee: This program operates stand-alone. It illustrates how to configure the
VT1419A to collect data, store that data into its FIFO and retrieve that data for
display on a strip chart and optional logging to a file. This program can also be used
to read stored data files generated by both this examples and the panl1419.vee
example. The example can easily be modified to a more complicated version or
pieces can be cut and pasted where needed.
The first object, Setup/Configure, can be used to configure the VT1419A trigger
subsystem, SCPs, and data formats. Since the VT1419A comes pre-configured with
four analog input SCPs in the first four slots, this example will concentrate only on
those channels and leave them configured for voltage input. Since the example
panl1419.vee also assumes this condition, data stored by that example’s logging
function can also be read by this example. If desired, refer to the example
temp1419.vee to see how channels can be configured for temperature measurements
using SCPI commands. Chapter 3 also illustrates how to configure analog channels
for other measurements such as resistance, for example.
VEE Programming Examples
Simple Data Logger Example
Chapter 5 163
Figure 5-13: Simple Data Logger
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com