DCAM550 ToF Camera User Manual -20210906

8
3.2 Electrical Specifications
3.2.1 Recommended Operating Conditions
Parameter
Symbol
Conditions
Min
Typ.
Max
Units
DC Power
VDD
11
12
26
V
USB2.0
USB
4.75
5
5.5
V
Digital I/O
(Exposure_timing)
Vout
Work
mode
5
V
Digital I/O
(Ext_Trigger)
Vin
3.3
20
V
RS485
-12
12
V
Operating Temperature
Ta
-20
50
°C
Operating humidity
20
80
%
Storage humidity
20
80
%
Storage temperature
-30
70
°C
3.2.2 Power Consumption
Parameter
Conditions
Average
Max
Units
Range 0
350mm-1200mm @30fps
238
334
mA
Range 1
500mm-2800mm@30fps
374
545
mA
Range 2
800mm-4400mm@30fps
438
661
mA
Range 5
1200mm-6000mm@15fps
478
1196
mA
Note: 12V input voltage
3.2.3 Absolute Maximum Ratings
This is a stress rating only and functional operation of the devices at those or any
other conditions above those indicated in the operation listings of this specification is
not promised. Exposure to maximum rating conditions for extended periods may
affect device reliability
Parameter
Symbol
Conditions
Min
Typ.
Max
Units
DC Power
VDD
9
12
30
V
USB2.0
USB
-0.3
5
6
V
Digital I/O
(Ext_Trigger)
Vin
-0.3
20
V
RS485
-13.2
13.2
V
Operating Temperature
Ta
-20
50
°C