Datasheet

Properties Test conditions
Value
Unit
min. typ. max.
Peak Wavelength 1000 mA λ
Peak
855 nm
Centroid Wavelength 1000 mA λ
Centroid
850 nm
Radiant Flux 1000 mA Φ
e
500 800 mW
Radiant Intensity 1000 mA I
e
350 mW/sr
Forward Voltage 1000 mA V
F
1.5 2.2 2.5 V
Spectral Bandwidth 1000 mA Δλ 35 nm
Reverse Current 5 V I
REV
10 μA
Viewing Angle 1000 mA
50%
90 °
Electrical & Optical Properties:
Properties Test Conditions Bin Value Unit
min. typ. max.
Forward Voltage V
F
1000 mA 1 1.5 1.7 V
2 1.7 1.9 V
3 1.9 2.1 V
4 2.1 2.3 V
5 2.3 2.5 V
Radiant Flux Φ
e
1000 mA B 500 560 mW
C 560 620 mW
D 620 680 mW
E 680 740 mW
F 740 800 mW
Viewing Angle:
45°
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
100
0°
10°
20°
30°
40°
50°
60°
70°
80°
90°
-45°
-90
Relative Luminous Intensity (%)
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
KaS ZAn DIN ISO 2768-1m
DESCRIPTION
WL-SIMW SMD Infrared Ceramic
Waterclear
ORDER CODE
15435385A9050
SIZE REVISION STATUS DATE BUSINESS UNIT PAGE
3535
001.000 Valid 2015-11-10 eiPal 2/9
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.