Data Sheet

WPMDH1152401 / 171012402
MagI
3
C Power Module
VDRM Variable Step Down Regulator Module
we-online.com Würth Elektronik eiSos GmbH & Co. KG Data Sheet Rev. 2.0
© December 2017
34/54
OUTPUT VOLTAGE RIPPLE
The output voltage ripple of the V
OUT
depends on several parameters, as already shown in DESIGN FLOW Step4. The
operating mode (CCM or DCM) further influences the output voltage ripple as shown in the two figures below:
The output voltage ripple during CCM operation is much lower (10mV
pp
) than the ripple during DCM operation (around
27mV
pp
).
-30
-20
-10
0
10
20
30
0 20 40 60 80 100 120
Output Voltage Ripple [mV]
Times]
V
OUT ripple
V
IN
= 24V, V
OUT
= 12V, I
OUT
= 50mA - DCM operation
27mV
-30
-20
-10
0
10
20
30
0 2 4 6 8 10 12 14 16 18 20
Output Voltage Ripple [mV]
Times]
V
OUT ripple
V
IN
= 24V, V
OUT
= 12V, I
OUT
= 2A - CCM operation
10mV