In order to choose the value of the output capacitor, the following steps should be followed:
1. According to the operating conditions (V
IN
, V
OUT
and f
SW
), select the minimum C
OUT
recommended in table on
page 38.
2. Measure t
d
.
3. Calculate the appropriate value of C
OUT
for the maximum voltage drop V
discharge
allowed at a defined load step,
using the following equation (10), derived from equation (9):
4. As above mentioned, changing C
OUT
affects also t
d
. Therefore a new measure should be performed and, if
necessary, the step 2 and 3 should be repeated (it is an iterative process and few steps could be required).
Example. V
IN
= 12V, V
OUT
= 3.3V, ΔI
OUT
= 2A (from 0.5A to 2.5A), f
sw
= 400kHz, ΔV
OUT
<0.1V.
According to the table on page 38, two output MLCC of 47µF would be necessary. After mounting these capacitors, the
load transient should be performed and the t
d
measured (see picture below).
The ΔV
OUT
= 0.13V and t
d
= 3µs. It is important to remind that the ΔV
OUT
includes also the voltage drop during t
rise
, mainly
due to the ESR (V
ESR
= 60mV, see picture above). In order to achieve the desired maximum ΔV
OUT
, the V
discharge
should be
below 0.025V. Using the equation (9), the minimum required output capacitor is:
To achieve the calculated value of C
OUT
, an additional MLCC of 47µF is mounted in parallel.
-0,3
-0,2
-0,1
0
0,1
0,2
0,3
-4
-3
-2
-1
0
1
2
3
4
0 10 20 30 40 50 60
V
OUT
(AC coupled) [V]
I
OUT
[A]
time [µs]
Load transient with C
OUT
= 47µF MLCC
ΔV
OUT
= 0.29V
6µs
V
discharge
= 0.2V
V
OUT
I
OUT