Datasheet

WPMDL9500xx / 17395xx78
MagI
3
C Power Module
FDSM - Fixed Step Down Regulator Module
ABSOLUTE MAXIMUM RATINGS
OPERATING CONDITIONS
Operating conditions are conditions under which operation of the device is intended to be functional. All values
are referenced to GND and to a free ambient operating temperature of T
A
= 25°C ± 5°C unless otherwise speci-
fied.
Caution:
Exceeding the listed absolute maximum ratings may affect the device negatively and may cause permanent
damage.
SYMBOL PARAMETER LIMITS UNIT
V
IN
Input voltage -0.3 to 30 V
V
ESD
ESD voltage (Human Body Model)
(1)
-2000 to +2000 V
T
ST
Storage temperature -55 to 125 °C
SYMBOL PARAMETER MIN
(3)
TYP
(4)
MAX
(3)
UNIT
V
IN
Input voltage (173950378) 3.3V
OUT
version 6 - 28 V
V
IN
Input Voltage (173950578) 5V
OUT
version 7 - 28 V
T
A
Ambient temperature range
(2)
-40 - +85 °C
I
OUT
Output current 5 - 500 mA
C
LOADMAX
Maximum capacitive load - - 220 µF
we-online.com
3 / 12
Würth Elektronik eiSos GmbH & Co. KG - Data Sheet - Rev 1.0
THERMAL SPECIFICATIONS
SYMBOL PARAMETER MIN
(3)
TYP
(4)
MAX
(3)
UNIT
Θ
JA
Thermal resistance junction to ambient 166 K/W