Data Sheet

Dimensions: [mm]
detail A
0,03
PET-Film
0,2 ref
Ferrite
0,05
Adhesive Tape
60,00 ±0,5
60,0 ±0,5
Release Tape
A
Scale - 1:2
Properties Value Unit Tol.
Complex Permeability
µ
@ 1 MHz
230 typ.
Complex Permeability
µ
@ 13.56 MHz
150 typ.
Complex Permeability
µ
@ 1 MHz
2 typ.
Complex Permeability
µ
@ 13.56 MHz
90 typ.
Adhesive Thickness 0.05 mm max.
Surface Resistance
1)
R
S
1 min.
Insulation Resistance
2)
R
ISO
1 min.
Peel Adhesion over Steel 6 N/ cm min.
Electrical Properties:
1)
Measured over the PET surface. Method ASTM D257-07
2)
Measured between the top PET layer and the bottom Adhesive later. Method ASTM D257-07
Storage Temperature (in original
packaging)
-40 °C up to +85 °C
Operating Temperature -40 °C up to +85 °C
Test conditions of Electrical Properties: +20°C, 33% RH if not specified differently
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
KaS JoV DIN ISO 2768-1m
DESCRIPTION
WE-FSFS Flexible Sintered Ferrite
Sheet
ORDER CODE
354005
REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
001.003 Valid 2016-02-23 eiSos 1/4
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.

Summary of content (4 pages)