Datasheet

BATT
TERM
FAULT
M3
M4
TS-CTRL
240 ms
240 ms
bq51013B
SLUSB62A MARCH 2013REVISED OCTOBER 2013
www.ti.com
Figure 39. Timing Diagram for TS Detection Circuit
3-state Driver Recommendations for the TS-CTRL Pin
The TS-CTRL pin offers three functions with one 3-state driver interface
1. NTC temperature monitoring,
2. Fault indication,
3. Charge done indication
A 3-state driver can be implemented with the circuit in Figure 40 and the use of two GPIO connections.
Figure 40. 3-state Driver for TS-CTRL
Note that the signals “TERM” and “FAULT” are given by two GPIOs. The truth table for this circuit is found in
Table 6:
Table 6.
TERM FAULT F (Result)
1 0 Z (Normal Mode)
0 0 Charge Complete
1 1 System Fault
The default setting is TERM = 1 and FAULT = 0. In this condition, the TS-CTRL net is high impedance (hi-z) and;
therefore, the NTC is function is allowed to operate. When the TS-CTRL pin is pulled to GND by setting FAULT =
1, the Rx is shutdown with the indication of a fault. When the TS-CTRL pin is pulled to the battery by setting
TERM = 1, the Rx is shutdown with the indication of a charge complete condition. Therefore, the host controller
can indicate whether the Rx is system is turning off due to a fault or due to a charge complete condition.
Thermal Protection
The bq5101xB includes a thermal shutdown protection. If the die temperature reaches T
J
(OFF), the LDO is shut
off to prevent any further power dissipation. In this case bq51013B will send an EPT message of internal fault
(0x02).
28 Submit Documentation Feedback Copyright © 2013, Texas Instruments Incorporated