Datasheet

Customer :
Ordercode:
Description :
Package:
U I/O to GND VDD to GND
0,5 0,1 0,1
9 0,1 0,1
9,5 0,1 0,1
I/O start
4,8 0,2
I/O end
9 17
VDD start
4,4 0,2
VDD end
6,5 17
A 0.60 mm
B 1.10 mm
C 0.95 mm
D 2.50 mm
E 1.40 mm
F 3.60 mm
W13: Device Code
X: Date Code
Y: Control Code
Specification for release
Würth Elektronik eiSos GmbH & Co. KG
TVS Diode Array WE-TVS
E
Typical Characteristic:
D-74638 Waldenburg · Max-Eyth-Strasse 1 · Germany · Phone (+49) (0) 7942 - 945 - 0 · Fax (+49) (0) 7942 - 945 - 400
SOT23-6L
http://www.we-online.com
DATUM / DATE : 2012-02-22
F
Recommended Land Layout:
824013
G
Body Marking:
Transmission Line Pulsing (TLP) Measurement Transmission Line Pulsing System
0,0
2,0
4,0
6,0
8,0
10,0
12,0
14,0
16,0
18,0
0 2 4 6 8 10
TLP Current [A]
TLP Voltage [V]
I/O to GND
VDD to GND
DUT
Rise time: 1ns
100ns
Pulse
V
I
A
E
B
F D
C
6
5
4
1
2
3
W
13