Installation Sheet
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Tube Architectural - Ceiling Mount
DS-CD05, DS-CD06, DS-CD08
OVERVIEW
It is surface mount down light, included ceiling mount, pendant mount, single direction wall wash and up-down direction wall wash.
Check WAC Lighting catalog for various mount type, size, beam angle and color choices.
FIXTURE INSTALLATION
1. Carefully unpack your new xture and lay out all the parts on a clear area. Be carefully not to lose any small parts necessary for installation.
(See FIG.1)
2. Remove the screw on side of xture holding mounting plate to xture, and remove mounting plate from xture. (See FIG.2)
3. Secure mounting plate to the junction box in ceiling provided by others.
4. Pull power supply wires out of junction box through mounting plate. Connect black xture wire to hot wire, white xture wire to neutral
wire and green xture wire to ground. This xture oers 0-10V dimming capability. To utilize, connect purple xture wire to hot dimming
wire and gray xture wire to neutral dimming wire. If not utilizing dimming, terminate the dimming wires by capping them separately. After
wires are connected securely, tuck them carefully inside the junction box .
5. Place the xture over the mounting plate, up to plate and rotate clockwise, then secure with screws and gasket.(See FIG.3)
Junction Box
Mount Plate
Gasket
Screw
Ground Wire
Secure the xture
screw and gasket
Up to plate and rotate
clockwise
FIG.2 FIG.3