Installation Sheet

Retain these instructions for future service and adjustments
44 Harbor Park Drive, Port Washington, NY 11050
Tel: (800) 526-2588 Fax (800) 526-2585
www.waclighting.com
INSTRUCTIONS Class II Electronic Transformer
Model EN-1260-RB2
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
Always turn off power at main switch prior to installation.
Intended for installation by a qualified electrician.
System is intended for installation in accordance with National Electric Code, and local
regulations. Consult with local inspector to assure compliance.
MAX LOAD 60W
MIN LOAD 20W
INPUT VOLTAGE 120V
INPUT CURRENT 0.53A
OUTPUT VOLTAGE 11.6V
CASE TEMP
90ºC (194F)
AMBIENT TEMP
-20ºC TO 50ºC (-4F TO 122F)
FEATURES:
Electronic short circuit protection with auto-reset.
Overload protection with auto-reset.
Automatic thermal regulation.
Soft start delay to preserve bulb life, for use with tungsten filament lamps.
INSTALLATION
1. Use a minimum of #18 AWG for the output wire.
2. Transformers must be installed away from heat sources and accessible for service.
3. Note: Enclosed transformer is UL listed. The transformer box has a separate line volt,
and low volt wiring compartments. Trade size knock out are provided on both
compartments. Connect building wires to like color transformer wires with wire nuts.
Building ground wire may be green or un-insulated, and attaches to green wire from
transformer box.
4. Connect out put wires from transformer to fixture wires with wire nuts. Where multiple
fixtures are involved several fixtures wires can be joined by use of the same wire nut.
Wires to fixture