Instruction Sheet
INSTRUCTIONS Class II Plug-in Electronic Transformer
Model: EN-1260-P-AR
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
• Always turn off power at main switch prior to installation.
• For installation by a qualified electrician.
• System is intended for installation in accordance with National Electric Code, and local
regulations. Consult with local inspector to assure compliance.
MAX LOAD 60W
MIN LOAD 20W
INPUT VOLTAGE 120V
INPUT CURRENT 0.53A
OUTPUT VOLTAGE 11.6V
MAX CASE TEMP
75ºC (167°F)
AMBIENT TEMP
-20ºC TO 50ºC (-4°F TO 122°F)
FEATURES:
• Electronic short circuit protection with auto-reset.
• Overload protection with auto-reset.
• Automatic thermal protection.
• Soft start delay to preserve bulb life, for use with tungsten filament lamps.
• Convenient on/off switching ability.
• Includes 6’ detachable cord.
INSTALLATION:
Transformer plugs into standard 120 volt 3 prong grounded outlet.
Transformers must be installed away from heat sources.
Output wires may run direct to the fixture leads, or longer (heavier gauge) wire maybe spliced in.
Class II output splices do not require enclosures.
Note: Transformer output is sufficient to power a 60 watt load up to six feet away. It is
recommended to use not more than 40 watts load when longer wire runs are necessary.
MAXIMUM LENGTH / VOLTAGE DROP GUIDELINE
WIRE SIZE 35 WATT 50 WATT 60 WATT
18 GAUGE 10 FT 9 FT 8 FT
16 GAUGE 14 FT 13 FT 11 FT
14 GAUGE 21 FT 19 FT 15 FT
12 GAUGE 28 FT 25 FT 21 FT
Retain these instructions for future service and adjustments