INSTALLATION INSTRUCTION
60W, 75W Enclosed Electronic Transformers
EN-1260N-R2
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
• Always turn o power at main switch prior to installation.
• Intended for installation by a qualied electrician.
• System is intended for installation in accordance with National Electric Code, and local regulations.
Consult with local inspector to assure compliance.
MAX LOAD 60W
MIN LOAD 1W
INPUT VOLTAGE 120V
INPUT CURRENT 0.53A
OUTPUT VOLTAGE 11.6V
CASE TEMP 90ºC (194°F)
AMBIENT TEMP -20ºC TO 50ºC (-4°F TO 122°F)
FEATURES
• Electronic short circuit protection with auto-reset.
• Overload protection with auto-reset.
• Automatic thermal regulation.
• Soft start delay to preserve bulb life, for use with tungsten lament lamps.
INSTALLATION:
1. Transformers must be installed away from heat sources and accessible for service.
2. Unit is a UL listed component for replacement purposes, requires junction box or listed enclosure.
3. Dimmer switches install on the primary side.
4. Connect building wires to like color transformer wires with wire nuts. Building ground wire may be green or un-insulated,
and attaches to the ground screw on an enclosure.
5. Wires to xtures may be chain wired or “ home run” wired back to the transformer. High frequency output is only readable
with a true RMS meter, with sucient range capability.