INSTALLATION INSTRUCTION
277V 96W Electronic Transformer
EN-24100-277-RB2-T
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
• Read all instructions before installing.
• System is intended for installation by a qualified electrician in accordance with the National Electrical Code and
local regulations.
• Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch “OFF”
the circuit breaker switch(es) that control the power to the fixture or room that you are working on.
• Place the wall switch in the “OFF” position.
AVERTISSEMENT:
IMPORTANT : COUPEZ L’ÉLECTRICITÉ AVANT TOUTE MANIPULATION.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
HARDWARE:
Wire Connector
Qty: 5pcs
Cover Screw
Qty: 2pcs
Mounting Screw
Qty: 2pcs
24V Tape Light
6ft Output Wire
Qty: 1pc
24V Straight Edge
Line 6ft Output Wire
Qty: 1extra
MAX LOAD 96W
MIN LOAD 1W
INPUT VOLTAGE
120-240VAC 1.4A 50/60Hz
277VAC 0.45A 50/60Hz
OUTPUT VOLTAGE 24.0VDC 4AMAX
AMBIENT TEMP -20ºC TO 50ºC (-4°F TO 122°F)
PRODUCT DIMENSIONS:
1w”
10a”
12s”
d” 2”
34”
4”
2”
A1 B1 D1 F1E1