Installation Instructions
44 Harbor Park Drive
Port Washington, NY 11050
Tel: 516.515.5000
Fax: 516.515.5050
www.waclighting.com
Installation Instructions: H Series Track
Safety Instructions:
1. Read all of these instructions before installing the track system.
2. Turn off power at main switch before installing or modifying the system.
3. Do not install within six inches of any curtain or combustible materials.
4. Do not install less than 5 feet above a floor.
5. Do not install in damp or wet locations.
6. Do not install concealed, or extended through building walls.
7. Do not attempt to energize anything other than a track light fixture.
8. Do not connect a track to more than one branch circuit. Although track light systems may seem to operate
acceptably, a dangerous overload of the neutral may occur and result in a risk of fire.
9. Check with a qualified electrician before wiring.
10. All installation shall be in accordance with NEC and all local codes
11. Save these installation instructions and refer to them when additions or changes to the track configuration
are made.
Electrical Feed From A Junction Box with
Floating Canopy
The floating canopy covers a junction box and brings
power to the track anywhere along its length.
1. Make sure power is off.
2. Remove the electrical adapter from the mounting
plate.
3. Secure mounting plate to the junction box using
the slotted holes
4. Hold track to the ceiling and mark the position of
mounting holes, set the position of the mounting
plate. Screw tabs facing downward.
5. Mount track to ceiling following track mounting
instructions (see track mounting section).
6. Secure track to the mounting plate. Tighten the
screws on both sides.
7. Insert electrical adapter into track below junction
box. Route wires along the side of track into the
junction box.
8. Connect neutral (white) and hot (black) wires
from the ceiling with their respective wires from
the track adapter.
9. Connect ground wire from ceiling to green
grounding wire from adapter.
10. Tuck excess wire back into the junction box.
11. Replace canopy cover and secure with screws.
Junction box
Mounting plate
Screw tab
Electrical adapter
Cover