Installation Instructions

44 Harbor Park Drive
Port Washington, NY 11050
Tel: 516.515.5000
Fax: 516.515.5050
www.waclighting.com
Field Cutting Track Continued
2. Do not allow bus wires and insulation to protrude from the end and do not cut the wires and push
insulation back into the track.
3. Make a flush cut through track with a fine-toothed hacksaw. File any rough edges or flash. Brush out
any remaining filings.
4. Once the flush cut is made trim 1/4” off the end of the copper bus wire. This will allow sufficient
clearance for the end cap for a mating connector. If not performed in this sequence the bus wires will
be short and cause faulty contact.
5. When mating to connector already at ceiling level make sure to support connectors at both ends.
1/4”