Specification Sheet
Fixture Type:
Catalog Number:
Project:
Location:
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Avenue • Ontario, CA 91760
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. SEP 2014
H TRACK CURRENT LIMITER
120V Track System
Model H Track Circuit Breaker Max Wattage Finishes Dimensions
Single Live End
THLHLE1A 1 × 1A 1 × 120W
BK
BN
DB
WT
Black
Brushed Nickel
Dark Bronze
White
72” × 5” × 14”
THLHLE2A 1 × 2.5A 1 × 300W
THLHLE5A 1 × 5A 1 × 600W
THLHLE7A 1 × 7.5A 1 × 900W
THLHLE10A 1 × 10A 1 × 1200W
Double Live End
THLHI11A
THLHI21A
1 × 1A
2 × 1A
1 × 120W
2 × 120W
THLHI12A
THLHI22A
1 × 2.5A
2 × 2.5A
1 × 300W
2 × 300W
THLHI15A
THLHI25A
1 × 5A
2 × 5A
1 × 600W
2 × 600W
THLHI17A
THLHI27A
1 × 7.5A
2 × 7.5A
1 × 900W
2 × 900W
THLHI110A
THLHI210A
1 × 10A
2 × 10A
1 × 1200W
2 × 1200W
Double Live End
(Left)
THLLEFT11A
THLLEFT21A
1 × 1A
2 × 1A
1 × 120W
2 × 120W
THLLEFT12A
THLLEFT22A
1 × 2.5A
2 × 2.5A
1 × 300W
2 × 300W
THLLEFT15A
THLLEFT25A
1 × 5A
2 × 5A
1 × 600W
2 × 600W
THLLEFT17A
THLLEFT27A
1 × 7.5A
2 × 7.5A
1 × 900W
2 × 900W
THLLEFT110A
THLLEFT210A
1 × 10A
2 × 10A
1 × 1200W
2 × 1200W
Double Live End
(Right)
THLRIGHT11A
THLRIGHT21A
1 × 1A
2 × 1A
1 × 120W
2 × 120W
THLRIGHT12A
THLRIGHT22A
1 × 2.5A
2 × 2.5A
1 × 300W
2 × 300W
THLRIGHT15A
THLRIGHT25A
1 × 5A
2 × 5A
1 × 600W
2 × 600W
THLRIGHT17A
THLRIGHT27A
1 × 7.5A
2 × 7.5A
1 × 900W
2 × 900W
THLRIGHT110A
THLRIGHT210A
1 × 10A
2 × 10A
1 × 1200W
2 × 1200W
Example: THLLEFT11AWT
Low Cost Energy Code Compliance Made Easy
• Easy to install and assures compliance to
California Title 24 or ASHRAE 90.1 requirements
• Energy code track installations are subject to wattage
limitations based upon the size and usage of the space
• To order appropriate current limiter, select the model
number which corresponds to the H system
to the maximum allowable wattage
• May be mounted as a standard canopy, used in place of
an “I” connector or as a live-end
How It Works
• If the track is overloaded the current limiter
circuit breaker will trip and
shut down power to the track.
• May be reset when the overall sum
of xture wattages are reduced.
below the circuit breaker rating
• It’s that easy to ensure energy
ecient usage of track installations.
THL–HLE–1A
Output 1 × 120W
1A × 120V = 120W
max load carrying capacity
H-LED820
21W
H-LED820
21W
H-LED820
21W
H-LED820
21W
H-LED820
21W
H-LED820
21W
≤ 120W = 126W > 120W
+
+
+ +