Installation & Assembly

WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MARCH, 2014
INSTALLATION INSTRUCTION
Mini LED Multiple Spots - New Construction
MT-3LD111NA-F30/MT-3LD211NA-F30/MT-3LD311NA-F30
SAFETY INSTRUCTION
IMPORTANT: NEVER attempt any work without shutting o the electricity.
1. Read all of these instructions before installing the track system.
2. System is intended for installation by a qualied electrician in accordance with the National Electrical
Code and local regulations.
3. Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or
switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
4. Place the wall switch in the “OFF” position.
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
1. Lisez toutes les instructions avant d’installer.
2. Système est destiné à être installé par un électricien qualié en conformité avec le code national de
3. l’électricité et les règlements locaux.
4. Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position
d’arrêt («OFF »).
5. Placez l’interrupteur mural en position d’arrêt (« OFF »).
NEW CONSTRUCTION HOUSING MOUNTING:
1. Install mounting frame using two hanger bars, (24 1/2” max).
Bars are notched on the ends to t over T bars in suspended ceilings.
Hanger bars include a captive mounting screw-nail” for
ease of installation (as Fig.1). Align the bottom of the hanger bar
with the bottom of the wood joist. Secure the screw-nail”
on each end by screwdriver (as Fig.A), or by hammer (as Fig.B).
2. Slide xture along bar hangers into desired location.
Use locking screws to secure (as Fig.C).
3. Junction box is suitable for branch wiring and has trade size
knockouts and integral non-metallic sheathed cable connectors.
4. Remove spring latched junction box door and connect xture wires
to building wires: insert each supply wire into appropriate
junction box connector. Connect black xture wire to hot wire,
white xture wire to neutral wire and green xture wire to ground (as Fig.2).
5. Place all wiring and connectors back in wiring box and
replace junction box door.
6. When installing in drywall, cut a hole 4 1/8”X4 1/8” in the drywall.
Note: 3/4” inch maximum ceiling thickness.
7. Push the trim assembly up until the trim ring is ush to the ceiling
(as Fig.3, Fig.4 and Fig.5).
USE TEMPLATE SUPPLIED TO MAKE APPROPRIATE CUTOUT.
Model Cutout
MT-3LD111NA-F30
4 8 x 4 8
MT-3LD211NA-F30
8 4 x 4 8
MT-3LD311NA-F30
12 x x 4 8

Summary of content (2 pages)