SET SWITCH BAUD RATE:
The switches for setting the CAN0 Baud Rate and CAN1 on the front panel of the device:
Dip n° 1, 2, 3, 4 CAN1 setting;
Dip n° 5, 6, 7, 8 CAN0 setting.
Speed CAN1 BPS
Dip 1 Dip 2 Dip 3 Dip 4
Speed CAN0 BPS
Dip 5 Dip 6 Dip 7 Dip 8
10K ON OFF OFF OFF
20K OFF ON OFF OFF
50K ON ON OFF OFF
(*) 62.5K OFF ON OFF ON
100K OFF OFF ON OFF
125K ON OFF ON OFF
250K OFF ON ON OFF
500K ON ON ON OFF
800K OFF OFF OFF ON
1000K ON OFF OFF ON