UPDATE DEVICE:
Section “Update device” (Fig. 6):
In order to load the parameters or update the firmware in the
gateway, follow these instructions:
Turn off the Device.
Connect the Null Modem Cable Form your PC to the
Gateway.
Insert the Boot Jumper (see the Fig. 1 for more info).
Select COM port and press the “Connect” Button.
Turn on the device.
Check The BOOT Led. It must to Blink quickly (see the
Fig. 1 for more info).
Press the “Next” Button
Select which operations you want to do. Can select only
Firmware or only Project or both.
Press the “Execute update firmware” to start the upload.
When all the operation are “OK” turn off the device.
Disconnect the Boot jumper.
Disconnect the RS232 Cable.
Turn on the Device.
At this point the configuration/firmware on the device is
correctly update.