1.4 Remaining hazards
Units from the controller series UR are state of the art and safe to operate. A risk
of danger can occur when deployed and operated improperly by untrained
personnel.
In this manual remaining hazards are marked by the following warning symbol:
This symbol indicates that non-observance of the safety guide-
lines may cause hazards to persons even serious injury or death
and/or the possibility of property damage.
1.5 CE Conformity
The CE certicate is available at our company. We are pleased to send you a
copy of it. Please feel free and contact us to get a copy.
2 Model identication
UR4848 series includes three versions. Looking at the table here below it is
possible to nd the required model.
Power supply 24…230 Vac/Vdc +/-15% 50/60 Hz – 5,5 VA
UR484802 2 relays 5 A or 1 relay + 1 Ssr/V/mA
UR484803 2 relays 5 A + 1 Ssr/V/mA + RS485 + current transformer*
UR484804 3 relays 5 A + 1 Ssr/V/mA + current transformer*
* Models with current transformer input for “Loop Break Alarm” function.
3 Technical Data
3.1 General data
Indicators
4x0.40 inch displays
4x0.30 inch displays
Operating
temperature
Temperature 0-45 °C
Humidity 35..95 uR%
Sealing
IP65 front panel (with gasket)
IP20 box and terminals
Material PC ABS UL94VO self-extinguishing
Weight 165 g (-20ABC) / 185 g (-21/31ABC)
3.2 Hardware data
Analogue
imput
1: AN1 congurable via
software. Input: Thermocou-
ple type K, S, R, J. Automatic
compensation of cold junction
from 0°C to 50°C.
Thermoresistance:
PT100, PT500, PT1000, Ni100,
PTC1K, NTC10K (β 3435K).
Linear: 0-10 V, 0-20 or 4-20
mA, 0-40 mV.
Current transformer: 50
mA, 1024 points on version
UR484803/04. Potentiome-
ters: 6 KΩ, 150 KΩ.
Tolerance (25 °C) +/-0.2% ±1
digit for thermocouple input,
thermo resistance and V / mA.
Cold junction accuracy 0.1
°C/°C.
Impedance:
0-10 V: Ri>110 KΩ
0-20 mA: Ri<5 Ω
4-20 mA: Ri<5 Ω
0-40 mV: Ri>1 MΩ
Relay
output
2 Relays (
UR484802/03
).
3 Relays (UR484804).
Congurable as command
and / or alarm output.
Contacts
5 A - 250 V~.
Resistive load.
SSR/V/mA
output
1 Linear 0/4…20 mA /
SSR/0…10 Volt.
• DeselectingOUT2relayon
UR484802. Congurable
as command output or
retransmission of setpoint
or process.
Congurable:
• 0/4…20mA(Resolution6000
points, Rmax 500 Ω);
• 0…10Volt(Resolution9500
points, Rmin 300 Ω).
3.3 Software data
Regulation
algorithms
ON - OFF with hysteresis.
P, P.I., P.I.D., P.D. with proportional time.
Proportional
band
0...9999 °C or °F
Integral time 0,0...999,9 sec. (0 excludes integral function)
Derivative time 0,0...999,9 sec. (0 excludes derivative function)
Controller
functions
Manual or automatic Tuning, congurable alarms, pro-
tection of command and alarm setpoints, activation of
functions via digital input, preset cycle with Start / Stop.