User manual
20 - URDR0001 - User manual
7.7 Pre-Programmed Cycle
The pre-programmed cycle function activates by setting
Pr. cy
or
Pc.SS.
on
parameter 59
oP.Mo
.
Setpoint
Setpoint 2
Max.
power
Setpoint 1
Hold
Natural cooling
Time
Gradient
First selection (
Pr. cy
):
the controller reaches setpoint1
basing on the gradient set on
parameter 62
Grad.
, then it
reaches maximum power up to
setpoint 2. When the process
reaches maximum power, this
setpoint is maintained for the
time set on parameter 63
m a . ti .
On expiry, the command output
is disabled and controller di-
splays
stop
. Cycle starts at each activation of the controller, or via digital input
if it is enabled for this type of functioning (see parameter 61
d G t .i .
).
Setpoint
Setpoint 1
Hold
Natural cooling
Time
Gradient
Second selection (
Pr. cy
):
start-up is decided only on
activation of the digital input,
according to the setting of
parameter 61
d G t .i .
On start-up,
controller reaches setpoint 1 fol-
lowing gradient set in parameter
62
Grad.
When the process reaches this
gradient, it is maintained for the
time set on parameter 63
m a . ti .
On expiry, command output is disabled and the
controller displays
stop
.