55 c.frn . Conversion Frequency
Sampling frequency of analogue / digital converter.
NB: Increasing the conversion speed will slow down reading sta-
bility (ex: for fast transients, as pressure, it is advisable to increase
sampling frequency)
242H.
242 Hz (Maximum speed conversion)
123H.
123 Hz
62 H.
62 Hz
50 H.
50 Hz
39 H.
39 Hz
33.2H.
33.2 Hz
19.6H.
19.6 Hz
1 6 .7H .
16.7 Hz (Default) Ideal for ltering noises 50 / 60 Hz
12.5H.
12.5 Hz
10 H.
10 Hz
8.33H.
8.33 Hz
6.25H.
6.25 Hz
4 .1 7 H .
4.17 Hz (Minimum speed conversion)
56 u .FLt. Visualization Filter
Slow down the refresh of display, to simplify reading
di s .
Disabled with pitchfork (maximum speed of display update)
Default.
fi . o r.
First order lter with pitchfork
2. s. m .
2 Samples Mean
3. s . m .
3 Samples Mean
4. s . m .
4 Samples Mean
5. s . m .
5 Samples Mean