6.4 Lube Level Maintainer
The lube level maintainer system protects the engine from low oil
levels by providing an additional 6-quart oil reservoir. Oil from the
reservoir is gravity-fed from the oil reservoir (a) through the control
valve (b) and into the engine oil pan as needed.
The valve includes a sightglass (c) through which the oil level can be
seen. This oil level is the same as that measured by the engine
dipstick. A float inside the valve detects low oil levels and opens the
valve to supply the needed oil. The system is wired to the ECM and
includes a low oil shutdown in case the oil in the reservoir is depleted.
If the engine shuts down due to low oil, the ECM will display “FAULT
LOW OIL LEVEL”. Fill the engine and the additional oil reservoir with
oil before placing the generator back into service.
To prevent overfilling the engine with oil, place the shutoff valve (d) in
the closed position when moving or towing the generator. Once the
generator is in position, open the valve.