Repair manual

RD 27 Troubleshooting the Vibration System
wc_tx000953gb.fm 79
5.10 Checking the Vibration Motor for Binding
Prerequisites
Machine shut down
Compactible surface
Background
By removing the exciter motor you’ll be able to check it along with the coupling and
the exciter shaft for binding.
Removal
Perform the procedure below to remove and check the exciter motor for binding.
1. Remove the hose protector plate (a).
2. Loosen the hose clamps (b).
3. Disconnect the hoses (c) from the exciter motor (d). To reduce the risk of
hydraulic system contamination, cap the hoses immediately after disconnecting
them. Dispose of spilled hydraulic oil in accordance with local environmental
protection regulations.
4. Remove the fittings (e, f) from the exciter motor.
This procedure continues on the next page.