Operator’s Manual Pump PS2 500 PS2A 500 PS2 750 Type PS2 500, PS2A 500, PS2 750 Document 5000187791 Date 1115 Version 04 Language EN 5 0 0 0 1 8 7 7 9 1
Copyright notice © Copyright 2015 by Wacker Neuson Production Americas LLC All rights, including copying and distribution rights, are reserved. This publication may be photocopied by the original purchaser of the machine. Any other type of reproduction is prohibited without express written permission from Wacker Neuson Production Americas LLC. Any type of reproduction or distribution not authorized by Wacker Neuson Production Americas LLC represents an infringement of valid copyrights.
PS 2 500 / PS 2 750 / PSA 2 500 Foreword Foreword SAVE THESE INSTRUCTIONS—This manual contains important instructions for the machine models below. These instructions have been written expressly by Wacker Neuson Production Americas LLC and must be followed during installation, operation, and maintenance of the machines.
Foreword PS 2 500 / PS 2 750 / PSA 2 500 Unapproved parts, attachments, and modifications are those that do not meet the approved criteria. Unapproved parts, attachments, or modifications may have the following consequences: Serious injury hazards to the operator and persons in the work area Permanent damage to the machine which will not be covered under warranty Contact your Wacker Neuson dealer immediately if you have questions about approved or unapproved parts, attachments, or modifications.
PS 2 500 / PS 2 750 1 Table of Contents Foreword 3 Safety Information 7 1.1 1.2 1.3 1.4 1.5 Signal Words Used in this Manual ....................................................... 7 Machine Description and Intended Use ............................................... 8 Operating and Electrical Safety ............................................................ 9 Service Safety .................................................................................... 10 Labels .............................
Table of Contents 6 PS 2 500 / PS 2 750 Technical Data 6.1 6.2 6.3 33 Standard Specifications .......................................................................33 Operating Specifications ....................................................................34 Dimensions ..........................................................................................34 7 Schematics 35 8 AEM Safety Manual 39 6 wc_bo5000187791_04TOC.
PS 2 500 / PS 2 750 / PSA 2 500 1 1.1 Safety Information Safety Information Signal Words Used in this Manual This manual contains DANGER, WARNING, CAUTION, NOTICE, and NOTE signal words which must be followed to reduce the possibility of personal injury, damage to the equipment, or improper service. This is the safety alert symbol. It is used to alert you to potential personal hazards. f Obey all safety messages that follow this symbol.
Safety Information 1.2 PS 2 500 / PS 2 750 / PSA 2 500 Machine Description and Intended Use This machine is a submersible water pump. The Wacker Neuson Submersible Pump consists of an electric motor, an impeller, a strainer, and a metal casing with ports for water suction and discharge. Power is supplied to the pump through a corded plug or a hard-wired connection, depending on the installation.
PS 2 500 / PS 2 750 / PSA 2 500 Safety Information To protect yourself and others, make sure you thoroughly read and understand the safety information presented in this manual before operating the machine. Operator qualifications Only trained personnel are permitted to start, operate, and shut down the machine.
Safety Information 1.4 PS 2 500 / PS 2 750 / PSA 2 500 Service Safety Service training Before servicing or maintaining the machine: • Read and understand the instructions contained in all manuals delivered with the machine. • Familiarize yourself with the location and proper use of all controls and safety devices. • Only trained personnel shall troubleshoot or repair problems occurring with the machine. • Contact Wacker Neuson for additional training if necessary.
PS 2 500 / PS 2 750 / PSA 2 500 1.5 Safety Information Labels Wacker Neuson Corporation Menomonee Falls, WI 53051 USA Model Item No. Man.Y/M Serial No. V Hz Max.m Phase Max.L/min kg Rev. THERMALLY PROTECTED INDOORS OR OUTDOORS CSA ENCLOSURE 3 Amp. Conforms to UL Std. 778 Cert. to CAN/CSA St d. C22.2 No.108-M89 kW R Max. ft Max.GPM lbs HP C L I STED 2001993 A nameplate listing the model number, item number, revision number, and serial number is attached to each unit.
Lifting and Transporting 2 PS 2 500 / PS 2 750 / PSA 2 500 Lifting and Transporting WARNING Do not under any circumstances install or move the pump by suspending it from the cable assembly. The cable may be damaged, causing electrical leakage, shock, or fire. When installing the pump, pay close attention to its center of gravity and weight. If it is not lowered into place correctly, it may fall and be damaged or cause injury.
PS 2 500 / PS 2 750 / PSA 2 500 3 Installation Installation 3.1 Components 1 7 2 8 9 10 11 12 13 14 3 4 5 6 wc_gr001185 Ref. Description Ref. 1 Lifting handle 8 Seal-mechanical 2 Coupling 9 Lubricant 3 Oil lifter 10 Seal-dust 4 Oil plug 11 Sleeve 5 Cover-suction 12 Housing-oil 6 Strainer 13 Wear ring 7 Cable assembly 14 Impeller wc_tx001971gb.
Installation 3.2 PS 2 500 / PS 2 750 / PSA 2 500 Preparing the Machine for First Use When the pump is delivered, first perform the following checks: • Inspection While unpacking, inspect the product for damage during shipment, and make sure all bolts and nuts are tightened properly. • Specification check Check the model number to make sure it is the product that was ordered. Be certain it is the correct voltage and frequency.
PS 2 500 / PS 2 750 / PSA 2 500 Installation Note: See “Operating Water Level” for the water level necessary for operation. The discharge end of the hose should be located higher than the water surface. If the end of the hose is submerged, water may flow back to the pump when the pump is stopped; and if the hose end is lower than the water surface, water may overflow when the pump is turned off. 3.3.
Installation CAUTION PS 2 500 / PS 2 750 / PSA 2 500 Model PSA2 500—Do not lift or hang the pump by the level relay unit (1). It will lead to damage and may cause leakage, electric shock, and fire See Graphic: wc_gr000259 1 wc_gr000259 16 wc_tx001971gb.
PS 2 500 / PS 2 750 / PSA 2 500 3.5 Installation Checks to Make Before Installation • When a grounded plug is used: Use the megohmmeter to measure the insulation resistance between the cable assembly prongs and ground. • When connection leads are used: With the megohmmeter, measure the insulation resistance between each core lead and the ground lead.
Installation 3.6 PS 2 500 / PS 2 750 / PSA 2 500 Electrical Wiring WARNING Performing electrical wiring Electrical wiring should be performed by a qualified person in accord with all applicable regulations. Failure to observe this precaution not only risks breaking the law but is extremely dangerous. Incorrect wiring can lead to current leakage, electrical shock or fire.
PS 2 500 / PS 2 750 / PSA 2 500 3.7 Installation Connecting the Power Supply WARNING CAUTION Before connecting leads to the terminal strip, make certain the power supply is turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or unexpected starting of the pump, leading to injury. Before inserting the power supply plug, make certain the power supply is turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or unexpected starting of the pump, leading to injury.
Installation 3.8 PS 2 500 / PS 2 750 / PSA 2 500 Cable Assembly CAUTION If it is necessary to extend the cable assembly, use a core size equal to or larger than the original. This is necessary not only to avoid a performance drop, but to prevent cable overheating which can result in fire, electrical leakage or electrical shock. If a cable with cut insulation or other damage is submerged in the water, there is a danger of damage to the pump, electrical leakage, electrical shock, or fire.
PS 2 500 / PS 2 750 / PSA 2 500 4 4.1 Operation Operation Before Starting 4.1.1 Make sure once again that the product is of the correct voltage and frequency rating. NOTICE: Using the product at other than rated voltage and frequency will not only lower its performance but may damage the product. Note: Confirm the rated voltage and frequency on the model nameplate. 4.1.2 Confirm the wiring, supply voltage, circuit breaker capacity, and motor insulation resistance.
Operation CAUTION WARNING PS 2 500 / PS 2 750 / PSA 2 500 COUNTERMEASURE: If the supply voltage is outside the tolerance, possible causes are the power supply capacity or an inadequate extension cable. Look again at the wiring diagram and make sure the conditions are proper. In case of very excessive vibration, unusual noise or odor, turn off the power immediately and consult your nearest dealer or Wacker Neuson representative.
PS 2 500 / PS 2 750 / PSA 2 500 4.2 Operation Operating Water Level CAUTION Do not operate the pump below the C.W.L. (Continuous running Water Level) indicated below. Failure to observe this condition may result in damage to the pump, current leakage or electrical shock. See Graphic: wc_gr001225 a b C.W.L 115 mm (4-1/2") PS 2 500, PS 2 750 PSA 2 500 wc_gr001225 Operating Water Level (PS 2 500, PS 2 750). Pump Model C.W.L.
Operation 4.3 PS 2 500 / PS 2 750 / PSA 2 500 Motor Protection System (Motor Protector) Circle Thermal protector (PS 2 750) Miniature Protector (PS 2 500, PSA 2 500) The pump has a built-in motor protection system.
PS 2 500 / PS 2 750 / PSA 2 500 Operation a a 1 b b 2 3 4 5 wc_gr000312 4.5 Emergency Shutdown Procedure If a breakdown/accident occurs while the machine is operating, follow the procedure below. wc_tx001986gb.fm 4.5.1 Turn off the pump. 4.5.2 Disconnect the power supply. 4.5.3 Contact the rental yard or machine owner.
Maintenance 5 PS 2 500 / PS 2 750 / PSA 2 500 Maintenance 5.1 Periodic Maintenance Schedule The table below lists basic machine maintenance. Tasks designated with check marks may be performed by the operator. Tasks designated with square bullet points require special training and equipment. Pump Weekly Measure insulation resistance. Reference insulation resistance = 1MΩ or greater. (1) Measure operating current. Compare with rated current. Measure supply voltage.
PS 2 500 / PS 2 750 / PSA 2 500 WARNING 5.1.1 Maintenance Regular maintenance and inspections are a necessity for continued efficient functioning of the pump. If any abnormal conditions are noticed, refer to the Troubleshooting section and take corrective measures immediately. It is recommended that a spare pump be kept ready in case of any problems. Prior to inspecting Before inspecting the pump, make certain the power supply (circuit breaker, etc.) is turned off.
Maintenance PS 2 500 / PS 2 750 / PSA 2 500 1 2 3 4 wc_gr001204 Ref. Description Ref. Description 1. Oil Inlet 3. Oil Plug 2. Gasket 4. Allen Wrench Pump Model Lubricant Capacity PS 2 400 160 ml (5.4 fl. oz.) PS 2 500, PSA 2 500 155 ml (5.2 fl. oz.) PS 2 750 210 ml (7.1 fl. oz.) 5.3 Replacement Parts The table lists the parts that need to be replaced periodically. Replace these using the recommended frequency as a guideline.
PS 2 500 / PS 2 750 / PSA 2 500 5.4 Maintenance Disassembly and Reassembly WARNING Before disassembling the pump, make certain the power supply (circuit breaker, etc.) is turned off. Then, unplug the cable assembly from the receptacle or detach it from the terminals. To avoid electrical shock, do not work with wet hands. Do not check the operation of any parts (impeller rotation, etc.) by turning on the power while the unit is partially assembled.
Maintenance 5.5 PS 2 500 / PS 2 750 / PSA 2 500 Disassembly See Graphic: wc_gr001206 5.5.1 Removing the strainer, suction cover, and volute: Remove the bolts (1) under the strainer (2), then remove the strainer, suction cover (3), and volute (4). 5.5.2 Removing the Impeller: With a box wrench or other tool, remove the acorn nut (6), lockwasher (7) and washer (8), then remove the impeller (9), sleeve (10) and dust seal (11) from the shaft. 5.5.
PS 2 500 / PS 2 750 / PSA 2 500 5.6 Maintenance Reassembly See Graphic: wc_gr001206, wc_gr001205 5.6.1 Mount the dust seal (11) onto the outside of the sleeve (10) as shown in the drawing. When doing so, do not apply oil or other lubrication to the surface where the dust seal contacts the sleeve (a). 5.6.2 When replacing the wear ring (12), make sure the front and back are oriented correctly. The side with the protrusions around the edge should face the volute (4).
Maintenance 5.7 PS 2 500 / PS 2 750 / PSA 2 500 Troubleshooting WARNING Before ordering repairs, carefully read through this manual, then repeat the inspection. If the problem remains, contact your nearest dealer or Wacker Neuson representative. ALWAYS turn off the power before inspecting the pump. Failure to observe this precaution can result in serious accident. Problem / Symptom Reason / Remedy Pump will not start • Power is off. Restore power. • Cable assembly is cut or not connected properly.
PS 2 500 / PS 2 750 / PSA 2 500 6 Technical Data Technical Data 6.
Technical Data 6.2 PS 2 500 / PS 2 750 / PSA 2 500 Operating Specifications Part No. PS 2 500 0009113 PSA 2 500 0009172 PS 2 750 0009114 0009115 0009116 Pump Electric Power V/Ph/Hz Rated Current A 110/1/60 220/1/60 110/1/60 110/1/60 220/1/60 6.1 3.0 6.1 11.5 6.5 Starting Method Capacitor-Run Bore mm (in.) Output kW (Hp) 50 (2) 0.48 (0.66) 0.75 (1) m (ft.) 12 (39.5) 18 (60) Maximum Capacity L/min (GPM) 236 (62.
PS 2 500 / PS 2 750 / PSA 2 500 7 Schematics Schematics R 1 R L B W W 3 2 5 G G/Y 6 4 wc_gr001201 PS 2 500 POWER SOURCE SINGLE PHASE Ref. Description Ref. Description 1 Capacitor 6 Ground 2 Main coil 7 Circle thermal protector 3 Auxiliary coil 8 Float switch (normally open contact) 4 Miniature protector 9 Heater 5 Frame grounding Wire Colors wc_tx002016gb.
Schematics PS 2 500 / PS 2 750 / PSA 2 500 1 3 2 R B 5 W W 4 R L B W 9 7 6 W G G/Y 10 8 wc_gr001202 PSA2 500 POWER SOURCE SINGLE PHASE Ref. Description Ref.
PS 2 500 / PS 2 750 / PSA 2 500 Schematics 1 R R R 3 1 2 R 2 3 W W 5 4 7 G G L 8 L 6 wc_gr001203 PS 2 750 POWER SOURCE SINGLE PHASE Ref. Description Ref. Description 1. Circle Thermal Protector 5. Centrifugal Switch 2. Auxiliary Coil 6. Capacitor 3. Heater 7. Frame Grounding 4. Main Coil 8.
Schematics PS 2 500 / PS 2 750 / PSA 2 500 Notes 38 wc_tx002016gb.
Important: For spare parts information, please see your Wacker Neuson Dealer, or visit the Wacker Neuson website at http://www.wackerneuson.com/. Wichtig! Informationen über Ersatzteile erhalten Sie von Ihrem Wacker Neuson Händler oder besuchen Sie die Wacker Neuson Website unter http://www.wackerneuson.com/. Important : Pour des informations sur les pièces détachées, merci de consulter votre distributeur Wacker Neuson, ou de visiter le site Internet de Wacker Neuson sur http://www.wackerneuson.com/.