Instructions / Assembly

Installation PS 2 500 / PS 2 750 / PSA 2 500
14 wc_tx001971gb.fm
3.2 Preparing the Machine for First Use
When the pump is delivered, first perform the following checks:
Inspection
While unpacking, inspect the product for damage during shipment, and
make sure all bolts and nuts are tightened properly.
Specification check
Check the model number to make sure it is the product that was
ordered. Be certain it is the correct voltage and frequency.
Note: If there is any problem with the product as shipped, contact your
nearest dealer or Wacker Neuson representative at once.
Product specifications
Do not operate this product under any conditions other than those for
which it is specified. Failure to observe this precaution can lead to
electrical shock, current leakage, fire, water leakage or other
problems.
3.3 Application Area
If the pump is used to drain a swimming pool, the pump must be
connected to a Ground Fault Interrupter (GFI).
If the pump is used in fountains, the pump must be connected to a
Ground Fault Interrupter (GFI).
The pump must not be used when people are in the water.
Leakage of pump lubricants may cause pollution of water.
Proper plug must be provided according to local codes and standards.
Refer to wiring diagram.
Do not use this pump in liquids other than water, such as oil, salt water,
or organic solvents.
Use with a power supply voltage within ±5% of the rated voltage.
Do not use in water temperatures outside the range of 0–40°C
(32–104°F) which can lead to failure, current leakage or shock.
Do not use in the vicinity of explosive or flammable materials.
Use only in fully assembled state.
Note: Consult your local dealer or Wacker Neuson representative
before using with any liquids other than those indicated in this
document.
3.3.1 Install the pump in a location with sufficient water level, where water
collects readily.
CAUTION
WARNING