Installation & Assembly (Queen)
Be sure to conrm the following information:
1. The installer has the qualications * and required knowledge.
2. Only wall anchor screws for wood-frame walls are provided with this bed. See anchor requirements and installation notes provided
in the instruction manual, according to the type of wall, and use the appropriate anchors such as described in this manual.
3. Your bed can hold a maximum distributed weight of 1000 lb (455 Kg), including the weight of the mattress.
4. Maximum thickness of mattress: 10 in (25.4 cm), and must stand in vertical position without sagging.
5. The bed will not stay open without the weight of the mattress which must be between: 45Lb (20 Kg) and 90 Lb (41 Kg).
6. Minimum ceiling height requirements for installation: 91.5 in (2.32 m).
IMPORTANT: BEFORE STARTING ASSEMBLY
INSTALLATION BY A QUALIFIED PERSON*
!
IMPORTANT WARNINGS:
RISK RESULTING FROM AN INCORRECT INSTALLATION
Only a qualied person * must carry out the installation and
any possible adjustment of the wall bed (including disassembly).
IMPROPER INSTALLATION OF THE WALL BED (RETRACTABLE BED) MAY CAUSE SERIOUS INJURIES TO THE INSTALLER, USERS OF THE BED AS WELL
AS THE PEOPLE NEAR THE BED. MORE SPECIFICALLY, IF THE WALL BED IS INSTALLED INCORRECTLY, IT COULD TIP, CLOSE UNEXPECTEDLY or
UNINTENTIONALLYWHEN IT IS OPEN, or OPEN UNEXPECTEDLY or UNINTENTIONALLYWHEN IT IS CLOSED, or ONE OF ITS STRUCTURAL
COMPONENTS MAY BREAK AND FALL OFF.
If you do not have the necessary skills*, make sure that the installation is done by a professional*. A good understanding of the wall structure
where the bed is anchored is necessary, including the positioning of the wall studs and structural components in the case of a wood or metal
structure. When you choose a professional f
DETERMINE THE FINAL LOCATION OF YOUR WALL BED (ON THE WALL AND ON THE FLOOR).
It is recommended to assess the structural integrity of the oor and wall and to make sure that the wall anchoring devices can withstand the forces
generated. More specically, before installing the wall bed, it is necessary to verify that the oor and the wall on which you want to install the bed
are at and have no structural damage that could aect the installation of the wall bed or its anchoring to the wall. Do not install the bed on weakened
or rotten structures.
* A CERTIFIED CONSTRUCTION PROFESSIONAL, IN COMPLIANCE WITH APPLICABLE REGULATIONS IN THE PROVINCE, STATE,
OR COUNTRY WHERE THE FURNITURE IS INSTALLED.
For future reference and to better serve you,
please complete and apply the self-adhesive
sticker in an accessible space such as the
back of part 60.
4
HARDWARE IN BOX 1
HARDWARE IN BOX 3
KI-993-A 1
KI-993-B 1
KI-993-C 1
KI-993-D 1
KI-993-E 2
KI-993-F 2
KI-993-G 1
KI-993-H 1
KI-993-I 1
KI-993-J 2
KI-985-K 12
KI-993-L 4
KI-993-M 12
KI-993-N 8
KI-993-O 3
KI-993-P 2
KI-993-Q 1
KI-993-R 4
KI-993-S 8
CODE QTÉ CODE QTÉ CODE QTÉ CODE QTÉ
14
AC-1009 1
CA-77 4
CA-99 2
CA-100 12
CA-1014 1
CH-838 8
CR-1041 1
EQ-1035 3
GO-796 16
H-03 4
H-36 4
KI-932-H 20
KI-985-K 2
PA-844 4
PL-1043 1
PO-1036 2
RO-994 8
RU-420 1
SU-1007 2
SU-1037 2
EQ-143 4
PO-1040 1
BT-1048 1
LEG WARNING STICKER
1
CODE QTÉ CODE QTÉ CODE QTÉ CODE QTÉ
1” (25 mm)
3/4” (18 mm)
Outside diameter
3/4” (19 mm)
3/8” (10 mm)
5/8” (15 mm)
3/32”
(
2,5 mm)
AC-1009-A
2 lights
AC-1009-B
Power supply
AC-1009-C
Switch
AC-1009-D
2 Extensions
Do not use the
screws included
5/8” (16 mm)
5/8” (16 mm)
1 3/4” (44 mm)
2 3/4” (70 mm)
Do not use the screws included
or the installation, ensure to observe all applicable laws.
HOLDING POWER
The value of the holding power (Fh) of each anchor should be 400 Newtons (90 Lb) if the wall bed is properly installed. At each use, the owner of the
wall bed should make sure that the anchors are strong and show no signs of weakening (for example if you feel that the anchor screws are moving
when pulling on the cabinet of the bed). Do not use the wall bed if the cabinet moves and do not open the bed if you are not sure that it is rmly
attached to the wall, because it could tip over causing serious injuries. When in doubt about the anchoring, please stop using the bed immediately
and have it inspected by a professional* or contact us.
Only a qualied person* must carry out the installation and any possible adjustment of the wall bed (including disassembly).
We are released from any responsibility if bed is not secured to the wall according to the recommendations included in this instruction leaet.
Keep proof of professional service use for the installation of your bed. These may be required for the application of the product warranty.