Owner Manual
FOR YOUR SAFETY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU ARE
WORKING ON IS SHUT OFF; EITHER THE FUSE IS REMOVED OR
THE CIRCUIT BREAKER IS SHUT OFF.
GENERAL
You don’t need special tools to install this xture. Be sure to follow
the steps in the order given. Under no circumstances should a xture
be hung on house electrical wires, nor should a swag type xture be
installed on a ceiling which contains a radiant type heating system.
Read instructions carefully. If you are unclear as to how to proceed,
consult a qualied electrician.
NOTE: Proper wiring is essential for the safe operation of this xture.
FIXTURE ASSEMBLY
Carefully remove the xture from the carton and check that all parts
are included as shown in gure. Be careful not to misplace any of the
screws or parts, which are needed to install this xture.
INSTALLATION
IMPORTANT: Do not attach xture directly to outlet box.
STEP 1: Turn OFF the power.
STEP 2: Remove the four Cap Nuts (16), and take out the Outer Ring
(15), then you can take the Acrylic Lens (14) out from the Fixture Pan (9).
STEP 3: Pull the Supply Wires (4 & 6) out from the Existing Outlet Box (1).
STEP 4: Position the xture over the Existing Outlet Box (1). Mark the
location of the four Key Hole Slots (17) located on the Fixture Pan (9).
Be sure to mark only the narrow parts of the Key Hole Slots (17).
Remove the Fixture Pan (9) from the ceiling. Drill the four holes using
the appropriately sized drill bit. Insert the provided Ceiling Anchors (8)
into the holes.
STEP 5: Make the wiring connections: connect the Fixture Ground
Wire (3) to the Existing Outlet Box (1); connect the White Supply Wire (4)
to the White Fixture Wire (5); connect the Black Supply Wire (6) to the
Black Fixture Wire (7) using Wire Connectors (2). Carefully tuck all wires
back into the Existing Outlet Box (1).
STEP 6: Reposition the xture over the Existing Outlet Box (1). Feed the
two Mounting Screws (13) through the holes located on the center of
the Fixture Pan (9). Tighten the Mounting Screws (13) into the threaded
holes on the Existing Outlet Box (1), and securing Mounting Plate (20).
STEP 7: Feed the four Anchor Screws (12) through the narrow part of
Key Hole Slots (17). Tighten the Anchor Screws (12) into the ceiling until
the Fixture Pan (9) is ush with the ceiling. Secure xture to Mounting
Plate (20) using Hand Screw Nut (21).
STEP 8:
Select desired color temperature using the Switch (19)
located within the xture.
STEP 9: Secure the Acrylic Lens (14) to the Fixture Pan (9), and take
up the Outer Ring (15) through the Threaded Pole (10) onto the Acrylic
Lens (14), and then tighten the Cap Nuts (16) into the Threaded Pole (10).
STEP 10: Turn ON the power.
GROUNDING INSTRUCTIONS
STEP 1: Insert the green grounding screw into the hole with two raised
dimples on the mounting bar. Wrap the ground wire from the xture (if
supplied) around the green grounding screw, then connect it to ground
wire from the outlet box (if not xed on the outlet box) using a wire
connector (not supplied). If ground wire from the xture is not supplied,
wrap the ground wire (if not xed on the outlet box) from the outlet box
around the green grounding screw and tighten it.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
STEP 2: Take note of the color of the wire(s) on your xture. Identify
which group your xture wire(s) falls into and connect the wires
according to the directions below:
GROUP A:
Connect to Black House Wire
GROUP B:
Connect to White House Wire
BLACK WHITE
* PARALLEL WIRE (round & smooth) * PARALLEL WIRE (square & ridged)
WHITE OR GREY WITH TRACER WHITE OR GREY WITHOUT TRACER
BROWN, GOLD OR BLACK
WITHOUT TRACER
BROWN, GOLD OR BLACK
WITH TRACER
NOTE: When parallel wire (SPT-I & SPT-2) is used, the tracer wire is
square shaped or ridged and the less tracer wire is round in shape or
smooth (seen best when viewed from wire end).
STEP 3: Take your xture wire(s) from group A and place evenly against
the black wire from the outlet box. Do NOT twist wires together before
using wire connectors.
STEP 4: Fit a wire connector over the wires and screw the connector
clockwise until you feel rmness.
STEP 5: Try gently to pull the connector off the wires. If you can pull
the connector off, carefully re-do steps 3 and 4 as above, and check
again for a rm connection.
STEP 6: Connect the xture wire from group B to the white wire from
the outlet box in the same manner. Make sure no bare wires can be
seen outside wire connectors.
CLEANING
To clean, wipe xture with a soft cloth. Clean glass with a mild soap.
Do not use abrasive materials such as scouring pads or powders, steel
wool or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. Be sure to use exact wording from illustration when
ordering parts.
FIGURE
Line art shown may not exactly match the xture enclosed. However, the installations
do apply to this xture.
La ilustración puede no concordar exactamente con la pieza enviada. Sin embargo,
las instalaciones sí aplican para esta pieza.
Les images peuvent ne pas correspondre exactement au luminaire de la boîte.
Par contre, les directives d’installation s’appliquent au luminaire.
INSTALLATION AND SAFETY INSTRUCTIONS
1
2
3
4
5
6
7
8
9
13
18
17
Existing Outlet Box
Wire Connector
Fixture Ground Wire
White Supply Wire
Black Supply Wire
White Fixture Wire
Black Fixture Wire
Ceiling Anchor
Fixture Pan
Mounting Plate
Switch
3000K/
4000K/
5000K
LED
Anchor Screw
Mounting Screw
Acrylic Lens
Outer Ring
Cap Nut
Key Slot
Drilled Holes
19
11
Hand Screw Nut
21
Threaded Pole