User manual

Performing a functional test MagicSafe MS660
78
7.6 Connecting the gas detector MSG150 (accessory)
(fig. k, page 11)
Disconnect the 12-volt plug from the gas detector cable.
Remove around 10 cm of the outer insulation on the end of the cable.
Connect the black cable to earth (terminal 31).
Connect the yellow and the orange cable of the gas detector to the white
cable from MS660.
Connect the red cable to a cable to a permanent +12 volt charge
(terminal +30). The cable must be fused with at least a 1 A fuse.
If the gas detector is also to be switched to the alarm system as the main
alarm, connect both the relay contacts as follows:
Connect the relay contact 1 (1) to earth (terminal 31).
Connect the relay contact 2 (2) to the grey/white cable of MS660.
8 Performing a functional test
8.1 Testing the hand-held transmitter
Test all of the switching functions with both hand-held transmitters.
If the system does not respond to a hand-held transmitter, program the hand-
held transmitter concerned (see chapter “Learning the hand-held transmitter,
electronic key and radio sensors/reading the PIN code” on page 91).
I
NOTE
The range of the hand-held transmitter can be restricted by solid
metal parts and strong electrical fields. It is usually between 10 m
and 20 m.