Performing a functional test MagicSafe MS660
80
Move an object into the vehicle interior from outside:
If an alarm is triggered before you move the object into the vehicle,
reduce the sensitivity.
If no alarm is triggered, increase the sensitivity.
I
NOTE for convertibles and vehicles with folding tops
For vehicles with cloth or plastic roofs, the sensitivity of the
ultrasonic sensors must be reduced significantly or be disabled
altogether.
Knock on the closed cover to check whether MagicSafe triggers the alarm
when the cover moves.
8.4 Testing other alarm inputs
Test the function of the other alarm inputs in order by triggering an alarm.
Count the number of flashes on the status LED afterwards.
If the number of flashes does not correspond to the specified value, you
need to check the connections and cables.
8.5 Testing optical and acoustic signals
Trigger an alarm.
During the alarm, all indicators must be switched on and the vehicle horn or
alarm siren, as well as the status LED, must signal the alarm.
Number of flashes Alarm cause
0 (status LED off) No alarm triggered
1 Voltage drop sensor
2 Ultrasonic sensors (interior)
3 Door/boot contact switch
4 Bonnet contact switch
5 Ignition
7 Additional alarm input
8 Radio sensor
9 The battery in the hand-held transmitter is too weak