9.2 Overview of parameters
“Change Run Mode” menu (operating mode)
“P.S. Mode Param” menu (power sharing mode)
Parameter Explanation
COMBI Power On The device acts as a charger and, if necessary, as an
inverter if there is not sufficient current at the AC input.
CHR Power On The device only acts as a charger. The inverter function is
deactivated.
Parameter Explanation Value range Default
Iac setup Power sharing level: limits the
current at the 230 V input (over-
load protection).
3 A – 25 A 3 A
Power
Sharing
Determines the power sharing
mode:
Disable = deactivated
GEN. = generator function
SUPP. = support function
SHAR. = power sharing
“SHAR.” enables the power
sharing function.
“SHAR. GEN.” enables the
power sharing and generator
functions.
“SHAR. SUPP.” enables the
power sharing and support func-
tions.
“SHAR. SUPP. GEN.” enables
the power sharing, support and
generator functions.
Disable
SHAR.
SHAR. GEN.
SHAR. SUPP.
SHAR. SUPP. GEN.
Disable
_CombiPower_IA_DE-IT.book Seite 93 Freitag, 21. Oktober 2011 8:10 20